The E250 is a workgroup-level Ultra Enterprise server, quite similar hardware-wise to the E450 and E420R.
The Aurora project has an E250 located in Westford, MA.
Tested Configurations
Aurora Version | Configuration | Remarks | Reporter |
1.0, 1.92 | 2x400MHz UltraSPARC-II, 1.5GB RAM, no video | Never really used the video (headless over serial). Otherwise works fine. | Dcbw? |
Detailed Specifications
(NOTE: These are the officially supported specifications - other hardware combinations may be possible but are not supported by Sun - see also Sun's System Handbook: [Enterprise 250])
CPU Architecture | 2 x 250-, 300- or 400-MHz UltraSPARC-II |
Cache Memory | 16-KB instruction cache, 16-KB data cache |
1 or 2 MB external cache | |
Main Memory | 16 DIMM module slots; four banks of four slots |
Accepts 32-, 64-, or 128-MB DIMMs | |
128 MB to 2 GB total memory capacity | |
Memory Type | 144-pin 5V 60-ns memory modules, ECC error-correction |
Standard Interfaces | |
Ethernet | One ethernet/fast ethernet (10BASE-T/100BASE-T) twisted-pair standard connector (RJ-45), self-sensing |
Keyboard/Mouse? | One standard keyboard/mouse port (mini DIN-8) |
Parallel | One IEEE 1284 (bidirectional) parallel port (DB25) |
PCI | Four full-size slots compliant with PCI specification version 2.1: |
One slot operating at 33- or 66-MHz, 32- or 64-bit data bus width, 3.3 volt | |
Three slots operating at 33 MHz, 32- or 64-bit data bus width, 5 volt | |
Serial | Two RS-232C/RS423 serial ports (DB25) |
SCSI | One 40MB/sec, 68-pin ,Ultra SCSI (SCSI-3), 2 channels (synchronous) |
Disks | Up to six 18-GB 3.5 x 1.6 in., 36-GB 3.5 x 1.0 in., 10000 rpm, hot-pluggable Ultra SCSI-3 drives |
Floppy | One 3.5-in. 1.44-MB floppy |
CDROM | SunCD? 32x 644-MB SCSI CD-ROM (standard; last order November 2000) |
Environmentals | |
AC input | 100 - 240 VAC, 47 - 63 Hz, 6.3 A(max) |
Input Power | 343 W |
Heat output | 1170 BTU/hr |
Temperature | Operating: 5° C to 35° C (41° F to 95° F) |
Nonoperating: -20° C to 60°° C (-4° F to 140° F) | |
Humidity | Operating: 20% to 80% relative humidity, noncondensing |
Nonoperating: 5% to 93% relative humidity, noncondensing | |
Altitude | Operating: 3000 m (10,000 ft.) |
Nonoperating: 12,000 m (40,000 ft) | |
Regulations | Meets or exceeds the following requirements: |
Safety | EN60950/IEC950 TUV, UL 1950, CB Scheme IEC 950, C22.2 No. 950 from UL |
RFI/EMI | EN55022/CISPR22 Class B, VCCI Class II FCC Part 15 Sub Part B |
Immunity | EN 50082-1 |
X-ray | DHHS 21 Subchapter J; PTB German X-ray Decree |
Dimensions | |
Height | 46.0 cm (18.1 in.) |
Width | 26.2 cm (10.3 in.) |
Depth | 68.8 cm (27.1 in.), power supply handles add 3.1 cm (1.2 in.) |
Weight | 53 kg (118 lb.) |